Instrumentation Cable
Flame Retardant
RE-2G(St)H-CI FE180 MP
RE-2G(St)H-CI FE180
RE-2G(St)H-CI-PIMF FE180
RE-2G(St)H-CI-TIMF FE180
RE-2G(St)HSWAH-CI FE180 MP
RE-2G(St)HSWAH-CI FE180
RE-2G(St)HSWAH-CI-PIMF FE180
RE-2G(St)HSWAH-CI-TIMF FE180
Product Download Files
Birtaş Kablo - Kumanda Kabloları 2YSLCY-J
Product Data Sheet
Local Quality Certificates
International Quality Certificates
Product Price List
Test Reports
Package Style
Summary Table
Reference Samples
MODERN CARTON
TÜPRAS
DOLPHIN PROJECT
ISKENDERUN STEEL
COLAKOGLU METALURJİ
PASABAHCE GLASS
INSTRUMENTATION CABLES
500V - Yangına Dayanıklı
RE-2G(St)H-CI-PIMF FE180
HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7
MULTI-PAIR, SILICONE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, HFFR SHEATHED
Marking

BIRTAS KABLO RE-2G(St)H-Cl PIMF FE 180 12 x 2 x 0.50mm2 2621 41 012 (HFFR) 90˚ C 500 V EN 50288-7 IEC 60331 Part no GOST-R CE....mt

Applications

These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.

Cable Design
ConductorPlain copper wire, stranded
IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2
InsulationSpecial silicone rubber compound
Core identificationBlack / Blue ; with numbered tape under
separator tape of the pair screen
Upon request ; Black / Blue cores numbered 1-1, 2-2,…
Other core configurations manufactured upon request.
PairTwo conductors twisted to a pair
PIMF ConstructionPolyester tape above the pair, AL-PES tape
over solid tinned copper drain wire, 0,60 mm
pon request ; Stranded 0,50 mm2 copper drain wire
Lay-upPIMF laid up in layers of optimum pitch
SeparatorPolyester tape
ScreenAL-PES tape over stranded tinned copper drain
wire 0,50 mm2
Outer sheathHFFR compound, EN 50290-2-27
Sheath colourRAL 9005, Black or RAL 5015, Blue
Technical Data
StandardTS/DIN EN 50288-7
(Designed according to)
Conductor resistance0,50mm2 : 36,7 Ω/km
0,75mm2 : 25,0 Ω/km
1,0mm2 : 18,5 Ω/km
1,3mm2 : 14,2 Ω/km
1,5mm2 : 12,3 Ω/km
Insulation resistanceMin. 300 MΩ.km
Mutual Capacitancemax. 150 pF/m
L / R (ratio) (max.)0,50mm2 : 25 µH/Ω
0,75mm2 : 25 µH/Ω
1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω
1,5mm2 : 40 µH/Ω
Rated voltage500V
Test voltageUrms core-core : 2000 V
Urms core-screen : 2000 V
Temperature rangeoperation : - 30 oC ~ + 90 oC
ınstallation : - 5 oC ~ + 50 oC
Min. bending radius7,5 x D
Flame testIEC 60332-1 & TS/DIN EN 60332-1
IEC 60332-3 & TS/DIN EN 50266-2-4
Smoke density testIEC 61034-2 & TS/DIN EN 61034-2
Halogen-free properties testIEC60754-1/2 & TS/DIN EN 50267-2
Circuit integrity (CI)IEC 60331 , VDE 0472-814
BS 6387 Cat. CWZ
Cross Section
Part-NumberNo. of Cores x
Cross Section (mm2)
Approx. Outer Diameter (mm)Copper Weight (Kg/km)Approx. Cable Weight (Kg/km)
2621 41 0022x2x0,5033,634101
2621 41 0044x2x0,5062,462155
2621 41 0055x2x0,5076,877189
2621 41 0066x2x0,5091,291217
2621 41 0088x2x0,50120120280
2621 41 01010x2x0,50148,8149335
2621 41 01212x2x0,50177,6178399
2621 41 01616x2x0,50235,2235516
2621 41 02020x2x0,50292,8293634
2621 41 02424x2x0,50350,4350753
2621 42 0022x2x0,7512,143121
2621 42 0044x2x0,7514,282197
2621 42 0055x2x0,7515,2101232
2621 42 0066x2x0,7516,6120276
2621 42 0088x2x0,7518,7158347
2621 42 01010x2x0,7520,7197427
2621 42 01212x2x0,7522,6235508
2621 42 01616x2x0,7525,8312658
2621 42 02020x2x0,7528,6389809
2621 42 02424x2x0,7531,2466960
2621 43 0022x2x112,453133
2621 43 0044x2x114,7101219
2621 43 0055x2x115,7125259
2621 43 0066x2x117,1149309
2621 43 0088x2x119,5197400
2621 43 01010x2x121,7245492
2621 43 01212x2x123,4293573
2621 43 01616x2x126,7389744
2621 43 02020x2x129,8485930
2621 43 02424x2x132,55811104
2621 44 0022x2x1,313,264151
2621 44 0044x2x1,315,6123253
2621 44 0055x2x1,316,9153308
2621 44 0066x2x1,318,3183358
2621 44 0088x2x1,320,8242465
2621 44 01010x2x1,323,1302572
2621 44 01212x2x1,325,2361680
2621 44 01616x2x1,328,7480884
2621 44 02020x2x1,331,96001087
2621 44 02424x2x1,334,87191291
2621 45 0022x2x1,513,872169
2621 45 0044x2x1,516,1139272
2621 45 0055x2x1,517,5173333
2621 45 0066x2x1,519,0206396
2621 45 0088x2x1,521,7274513
2621 45 01010x2x1,523,9341620
2621 45 01212x2x1,526,0408737
2621 45 01616x2x1,529,9542974
2621 45 02020x2x1,533,16771197
2621 45 02424x2x1,536,18111421
Top 